Hide metadata

dc.contributor.authorGonzales, Ricardo A.
dc.contributor.authorSeemann, Felicia
dc.contributor.authorLamy, Jérôme
dc.contributor.authorMojibian, Hamid
dc.contributor.authorAtar, Dan
dc.contributor.authorErlinge, David
dc.contributor.authorSteding-Ehrenborg, Katarina
dc.contributor.authorArheden, Håkan
dc.contributor.authorHu, Chenxi
dc.contributor.authorOnofrey, John A.
dc.contributor.authorPeters, Dana C.
dc.contributor.authorHeiberg, Einar
dc.date.accessioned2021-12-07T06:03:10Z
dc.date.available2021-12-07T06:03:10Z
dc.date.issued2021
dc.identifier.citationJournal of Cardiovascular Magnetic Resonance. 2021 Dec 02;23(1):137
dc.identifier.urihttp://hdl.handle.net/10852/89414
dc.description.abstractBackground Mitral annular plane systolic excursion (MAPSE) and left ventricular (LV) early diastolic velocity (e’) are key metrics of systolic and diastolic function, but not often measured by cardiovascular magnetic resonance (CMR). Its derivation is possible with manual, precise annotation of the mitral valve (MV) insertion points along the cardiac cycle in both two and four-chamber long-axis cines, but this process is highly time-consuming, laborious, and prone to errors. A fully automated, consistent, fast, and accurate method for MV plane tracking is lacking. In this study, we propose MVnet, a deep learning approach for MV point localization and tracking capable of deriving such clinical metrics comparable to human expert-level performance, and validated it in a multi-vendor, multi-center clinical population. Methods The proposed pipeline first performs a coarse MV point annotation in a given cine accurately enough to apply an automated linear transformation task, which standardizes the size, cropping, resolution, and heart orientation, and second, tracks the MV points with high accuracy. The model was trained and evaluated on 38,854 cine images from 703 patients with diverse cardiovascular conditions, scanned on equipment from 3 main vendors, 16 centers, and 7 countries, and manually annotated by 10 observers. Agreement was assessed by the intra-class correlation coefficient (ICC) for both clinical metrics and by the distance error in the MV plane displacement. For inter-observer variability analysis, an additional pair of observers performed manual annotations in a randomly chosen set of 50 patients. Results MVnet achieved a fast segmentation (<1 s/cine) with excellent ICCs of 0.94 (MAPSE) and 0.93 (LV e’) and a MV plane tracking error of −0.10 ± 0.97 mm. In a similar manner, the inter-observer variability analysis yielded ICCs of 0.95 and 0.89 and a tracking error of −0.15 ± 1.18 mm, respectively. Conclusion A dual-stage deep learning approach for automated annotation of MV points for systolic and diastolic evaluation in CMR long-axis cine images was developed. The method is able to carefully track these points with high accuracy and in a timely manner. This will improve the feasibility of CMR methods which rely on valve tracking and increase their utility in a clinical setting.
dc.language.isoeng
dc.rightsThe Author(s); licensee BioMed Central Ltd.
dc.rightsAttribution 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.titleMVnet: automated time-resolved tracking of the mitral valve plane in CMR long-axis cine images with residual neural networks: a multi-center, multi-vendor study
dc.typeJournal article
dc.date.updated2021-12-07T06:03:10Z
dc.creator.authorGonzales, Ricardo A.
dc.creator.authorSeemann, Felicia
dc.creator.authorLamy, Jérôme
dc.creator.authorMojibian, Hamid
dc.creator.authorAtar, Dan
dc.creator.authorErlinge, David
dc.creator.authorSteding-Ehrenborg, Katarina
dc.creator.authorArheden, Håkan
dc.creator.authorHu, Chenxi
dc.creator.authorOnofrey, John A.
dc.creator.authorPeters, Dana C.
dc.creator.authorHeiberg, Einar
dc.identifier.cristin2000559
dc.identifier.doihttps://doi.org/10.1186/s12968-021-00824-2
dc.identifier.urnURN:NBN:no-92022
dc.type.documentTidsskriftartikkel
dc.type.peerreviewedPeer reviewed
dc.identifier.fulltextFulltext https://www.duo.uio.no/bitstream/handle/10852/89414/1/12968_2021_Article_824.pdf
dc.type.versionPublishedVersion
cristin.articleid137


Files in this item

Appears in the following Collection

Hide metadata

Attribution 4.0 International
This item's license is: Attribution 4.0 International