Hide metadata

dc.contributor.authorLe Thieu, Minh K.
dc.contributor.authorHomayouni, Amin
dc.contributor.authorHæren, Lena R.
dc.contributor.authorTiainen, Hanna
dc.contributor.authorVerket, Anders
dc.contributor.authorEllingsen, Jan E.
dc.contributor.authorRønold, Hans J.
dc.contributor.authorWohlfahrt, Johan C.
dc.contributor.authorCantalapiedra, Antonio G.
dc.contributor.authorMuñoz, Fernando M. G.
dc.contributor.authorMendaña, Maria P.
dc.contributor.authorLyngstadaas, Ståle P.
dc.contributor.authorHaugen, Håvard J.
dc.date.accessioned2021-11-30T06:03:51Z
dc.date.available2021-11-30T06:03:51Z
dc.date.issued2021
dc.identifier.citationBiomaterials Research. 2021 Nov 25;25(1):43
dc.identifier.urihttp://hdl.handle.net/10852/89379
dc.description.abstractBackground Insufficient bone volume around an implant is a common obstacle when dental implant treatment is considered. Limited vertical or horizontal bone dimensions may lead to exposed implant threads following placement or a gap between the bone and implant. This is often addressed by bone augmentation procedures prior to or at the time of implant placement. This study evaluated bone healing when a synthetic TiO2 block scaffold was placed in circumferential peri-implant defects with buccal fenestrations. Methods The mandibular premolars were extracted and the alveolar bone left to heal for 4 weeks prior to implant placement in six minipigs. Two cylindrical defects were created in each hemi-mandible and were subsequent to implant placement allocated to treatment with either TiO2 scaffold or sham in a split mouth design. After 12 weeks of healing time, the samples were harvested. Microcomputed tomography (MicroCT) was used to investigate defect fill and integrity of the block scaffold. Distances from implant to bone in vertical and horizontal directions, percentage of bone to implant contact and defect fill were analysed by histology. Results MicroCT analysis demonstrated no differences between the groups for defect fill. Three of twelve scaffolds were partly fractured. At the buccal sites, histomorphometric analysis demonstrated higher bone fraction, higher percentage bone to implant contact and shorter distance from implant top to bone 0.5 mm lateral to implant surface in sham group as compared to the TiO2 group. Conclusions This study demonstrated less bone formation with the use of TiO2 scaffold block in combination with implant placement in cylindrical defects with buccal bone fenestrations, as compared to sham sites.
dc.language.isoeng
dc.rightsThe Author(s); licensee BioMed Central Ltd.
dc.rightsAttribution 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.titleImpact of simultaneous placement of implant and block bone graft substitute: an in vivo peri-implant defect model
dc.typeJournal article
dc.date.updated2021-11-30T06:04:10Z
dc.creator.authorLe Thieu, Minh K.
dc.creator.authorHomayouni, Amin
dc.creator.authorHæren, Lena R.
dc.creator.authorTiainen, Hanna
dc.creator.authorVerket, Anders
dc.creator.authorEllingsen, Jan E.
dc.creator.authorRønold, Hans J.
dc.creator.authorWohlfahrt, Johan C.
dc.creator.authorCantalapiedra, Antonio G.
dc.creator.authorMuñoz, Fernando M. G.
dc.creator.authorMendaña, Maria P.
dc.creator.authorLyngstadaas, Ståle P.
dc.creator.authorHaugen, Håvard J.
dc.identifier.cristin1959909
dc.identifier.doihttps://doi.org/10.1186/s40824-021-00245-3
dc.identifier.urnURN:NBN:no-91989
dc.type.documentTidsskriftartikkel
dc.type.peerreviewedPeer reviewed
dc.identifier.fulltextFulltext https://www.duo.uio.no/bitstream/handle/10852/89379/1/40824_2021_Article_245.pdf
dc.type.versionPublishedVersion
cristin.articleid43


Files in this item

Appears in the following Collection

Hide metadata

Attribution 4.0 International
This item's license is: Attribution 4.0 International