Hide metadata

dc.date.accessioned2022-12-20T16:40:54Z
dc.date.available2022-12-20T16:40:54Z
dc.date.created2022-08-03T12:11:21Z
dc.date.issued2022
dc.identifier.citationJohannsen, Christina Reubsaet, Leon Halvorsen, Trine Grønhaug . On the spot immunocapture in targeted biomarker analysis using paper-bound streptavidin as anchor for biotinylated antibodies. Analytical and Bioanalytical Chemistry. 2022, 414(19), 5979-5989
dc.identifier.urihttp://hdl.handle.net/10852/98256
dc.description.abstractAbstract The modification of an easily available resource like paper to circumvent expensive or intensive sample pretreatment could be the answer to sample analysis in resource-poor regions. Therefore, a novel on-paper device combining sample collection with affinity sample pretreatment is introduced here. Universal smart affinity samplers are produced by a simple KIO 4 -mediated oxidation of cellulose, which functionalizes the paper. This is followed by immobilization of streptavidin. Streptavidin serves as a universal anchor for biotinylated antibodies, enabling simple preparation of tailor-made affinity samplers. The functionality of the device was tested using a model protein (human chorionic gonadotropin, hCG) and biotinylated anti-hCG antibodies for affinity capture. In a laboratory setting, the performance was demonstrated, and a 14-fold increase of target binding compared to binding without bmAb was achieved. The recovery of hCG captured with bmAb-treated samplers was determined to be 33% and comparable to previously described affinity capture approaches. Application of the smart affinity samplers to human serum containing hCG showed an R 2 of 0.98 (200–1000 pg mL −1 ), precision of ≤ 9.1% RSD, and estimated limit of detection of 65 pg mL −1 . Although further optimization and validation are necessary prior to application to real samples in clinical settings, the potential of the device for use in determination of low abundant biomarkers in complex samples has been demonstrated.
dc.languageEN
dc.rightsAttribution 4.0 International
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.titleOn the spot immunocapture in targeted biomarker analysis using paper-bound streptavidin as anchor for biotinylated antibodies
dc.title.alternativeENEngelskEnglishOn the spot immunocapture in targeted biomarker analysis using paper-bound streptavidin as anchor for biotinylated antibodies
dc.typeJournal article
dc.creator.authorJohannsen, Christina
dc.creator.authorReubsaet, Leon
dc.creator.authorHalvorsen, Trine Grønhaug
cristin.unitcode185,15,29,0
cristin.unitnameInstitutt for biovitenskap
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1
dc.identifier.cristin2040890
dc.identifier.bibliographiccitationinfo:ofi/fmt:kev:mtx:ctx&ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Analytical and Bioanalytical Chemistry&rft.volume=414&rft.spage=5979&rft.date=2022
dc.identifier.jtitleAnalytical and Bioanalytical Chemistry
dc.identifier.volume414
dc.identifier.issue19
dc.identifier.startpage5979
dc.identifier.endpage5989
dc.identifier.doihttps://doi.org/10.1007/s00216-022-04161-w
dc.type.documentTidsskriftartikkel
dc.type.peerreviewedPeer reviewed
dc.source.issn1618-2642
dc.type.versionPublishedVersion


Files in this item

Appears in the following Collection

Hide metadata

Attribution 4.0 International
This item's license is: Attribution 4.0 International