Hide metadata

dc.date.accessioned2020-11-13T19:11:50Z
dc.date.available2020-11-13T19:11:50Z
dc.date.created2020-10-15T18:52:09Z
dc.date.issued2020
dc.identifier.citationNapoli, Elisa Stenberg, Vilde Yuli Juzeniene, Asta Hjellum, Gro E. Bruland, Øyvind Larsen, Roy H. . Calibration of sodium iodide detectors and reentrant ionization chambers for 212Pb activity in different geometries by HPGe activity determined samples. Applied Radiation and Isotopes. 2020, 166:109362, 1-9
dc.identifier.urihttp://hdl.handle.net/10852/81028
dc.description.abstractLead-212 is a promising radionuclide for cancer therapy, but no primary 212Pb activity standardization has been published. A need therefore exists for accurate estimation of injected doses of 212Pb activity in equilibrium with progeny, when it comes to preclinical and clinical trials. In this study, 212Pb activity was determined using a high purity germanium (HPGe) detector, which allowed the determination of geometry-specific calibration factors for commercially available reentrant ionization chambers (ICs) and sodium iodide (NaI) detectors.
dc.languageEN
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.titleCalibration of sodium iodide detectors and reentrant ionization chambers for 212Pb activity in different geometries by HPGe activity determined samples
dc.typeJournal article
dc.creator.authorNapoli, Elisa
dc.creator.authorStenberg, Vilde Yuli
dc.creator.authorJuzeniene, Asta
dc.creator.authorHjellum, Gro E.
dc.creator.authorBruland, Øyvind
dc.creator.authorLarsen, Roy H.
cristin.unitcode185,53,49,10
cristin.unitnameAvdeling for kreftbehandling
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1
dc.identifier.cristin1839971
dc.identifier.bibliographiccitationinfo:ofi/fmt:kev:mtx:ctx&ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Applied Radiation and Isotopes&rft.volume=166:109362&rft.spage=1&rft.date=2020
dc.identifier.jtitleApplied Radiation and Isotopes
dc.identifier.volume166
dc.identifier.doihttps://doi.org/10.1016/j.apradiso.2020.109362
dc.identifier.urnURN:NBN:no-84106
dc.type.documentTidsskriftartikkel
dc.type.peerreviewedPeer reviewed
dc.source.issn0969-8043
dc.identifier.fulltextFulltext https://www.duo.uio.no/bitstream/handle/10852/81028/1/Calibration%2Bof%2Bsodium%2Biodide%2Bdetectors%2Band%2Breentrant%2Bionization%2Bchambers%2Bfor%2B212Pb%2Bactivity%2Bin%2Bdifferent%2Bgeometries%2Bby%2BHPGe%2Bactivity%2Bdetermined%2Bsamples.pdf
dc.type.versionPublishedVersion
cristin.articleid109362