Hide metadata

dc.date.accessioned2020-08-07T18:46:30Z
dc.date.available2020-08-07T18:46:30Z
dc.date.created2020-06-12T11:28:14Z
dc.date.issued2020
dc.identifier.citationRahmati, Maryam Lyngstadaas, Ståle Petter Reseland, Janne Elin Andersbakken, Ingrid Haugland, Heidi Straume López-peña, Mónica Cantalapiedra, Antonio gonzalez Muñoz, Fernando maria guzon Haugen, Håvard Jostein . Coating doxycycline on titanium-based implants: two in vivo studies. Bioactive Materials. 2020, 5(4), 787-797
dc.identifier.urihttp://hdl.handle.net/10852/78213
dc.description.abstractRegardless of the substantial progress in designing titanium-based dental implants and aseptic techniques, infection remains as the most common complication after implantation surgeries. Although, having a weakened immune system or systematic diseases is not seen as contraindicated for dental implants anymore, controlling the immune system is required to avoid surgical site infections after implantation. These patients have to control the surgical site infections by taking a high daily dose of oral antibiotics after dental implantation. The antibiotics oral administration has many side effects such as gastrointestinal symptoms, skin rashes and thrush. Coating antibiotics on the biomaterials surface could be a promising solution to reduce these disadvantages through locally releasing antibiotics in a controlled manner. The aim of this study was to investigate the effects of doxycycline coating layer on titanium-zirconium alloy surfaces in vitro and in vivo. In our previous studies, we demonstrated the chemical presence of doxycycline layer in vitro. In this study, we examined its physical presence using field emission scanning electron microscope and confocal microscope. We also analyzed its controlled released manner using Nano-Drop UV Vis spectrometer. After in vitro characterization of the coating layer, we evaluated its effects on the implant osseointegration in dogs and rabbits. The histological and histomorphometrical results exhibited no significant difference between doxycycline coated and uncoated groups regarding the implants osseointegration and biocompatibility for dental applications. Therefore, coating a doxycycline layer on TiZr implants could be favorable for reducing or removing the antibiotics oral administration after the implantation surgery.
dc.languageEN
dc.rightsAttribution 4.0 International
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.titleCoating doxycycline on titanium-based implants: two in vivo studies
dc.typeJournal article
dc.creator.authorRahmati, Maryam
dc.creator.authorLyngstadaas, Ståle Petter
dc.creator.authorReseland, Janne Elin
dc.creator.authorAndersbakken, Ingrid
dc.creator.authorHaugland, Heidi Straume
dc.creator.authorLópez-peña, Mónica
dc.creator.authorCantalapiedra, Antonio gonzalez
dc.creator.authorMuñoz, Fernando maria guzon
dc.creator.authorHaugen, Håvard Jostein
cristin.unitcode185,16,17,62
cristin.unitnameBiomaterialer
cristin.ispublishedtrue
cristin.fulltextoriginal
dc.identifier.cristin1815215
dc.identifier.bibliographiccitationinfo:ofi/fmt:kev:mtx:ctx&ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Bioactive Materials&rft.volume=5&rft.spage=787&rft.date=2020
dc.identifier.jtitleBioactive Materials
dc.identifier.volume5
dc.identifier.issue4
dc.identifier.startpage787
dc.identifier.endpage797
dc.identifier.doihttps://doi.org/10.1016/j.bioactmat.2020.05.007
dc.identifier.urnURN:NBN:no-81307
dc.type.documentTidsskriftartikkel
dc.type.peerreviewedPeer reviewed
dc.source.issn2452-199X
dc.identifier.fulltextFulltext https://www.duo.uio.no/bitstream/handle/10852/78213/2/1-s2.0-S2452199X20300906-main.pdf
dc.type.versionPublishedVersion
dc.relation.projectNFR/231530
dc.relation.projectEC/H2020/811226


Files in this item

Appears in the following Collection

Hide metadata

Attribution 4.0 International
This item's license is: Attribution 4.0 International