Hide metadata

dc.date.accessioned2020-07-07T19:36:53Z
dc.date.available2020-07-07T19:36:53Z
dc.date.created2020-03-09T10:21:22Z
dc.date.issued2020
dc.identifier.citationDe-Deus, Gustavo Simões-Carvalho, M Belladonna, Felipe Goncalves Versiani, Marcio Silva, E. J. N. L. Cavalcante, D. M. Souza, E.M. Johnsen, Gaute Floer Haugen, Håvard Jostein Paciornik, S. . Creation of well-balanced experimental groups for comparative endodontic laboratorial studies: a new proposal based on micro-CT and in silico methods. International Endodontic Journal. 2020
dc.identifier.urihttp://hdl.handle.net/10852/77609
dc.description.abstractAim To introduce a new method to select anatomically matched teeth using micro-computed tomographic (micro-CT) technology. Methodology Single-rooted mandibular incisors with a single root canal (n = 60) were selected and distributed into three experimental groups according to the method used for matching 10 pairs of teeth in each group. In group 1, the pairs of mandibular incisors were randomly selected from a pool of teeth. In group 2, teeth were paired based on the measurement of canal width 5 mm from the root apex using radiographs taken from buccolingual and mesiodistal directions. In group 3, teeth were scanned (pixel size of 14.25 μm) and pair-matched based on the anatomical aspects of the root canal, named aspect ratio (AR), volume and three-dimensional canal geometry. After allocating the specimens into groups 1 and 2, the teeth were scanned and the canal morphology evaluated as in group 3. A bivariate Pearson’s regression analysis was performed correlating the individual AR values of each pair and the correlation coefficient was used to estimate the strength of the pair-matching process. One-way ANOVA post hoc Tukey tests were applied for pair-wise comparisons at a significance level of 5%. Results The micro-CT method showed 100% of the samples having strong (80%) or very strong (20%) correlations with respect to AR values. Analysis of the radiographic method revealed strong correlation in two pairs (20%), but most of the samples had weak (30%) or neglectable (30%) correlation coefficients. The randomization method resulted in 3 pairs (30%) with very strong correlations, while 50% had weak or neglectable rates. A significant difference in correlation coefficients was observed in the micro-CT method compared to the other groups (p < 0.05), whilst no difference was detected between radiographic and randomized methods (p > 0.05). Eta squared (η 2 ) calculations demonstrated a very high effect size in the micro-CT group for selecting pairs (0.99), and lower effect sizes in the radiographic (0.67) and randomized (0.66) groups. Conclusions Micro-CT method was able to provide better control of the confounding effect that
dc.languageEN
dc.titleCreation of well-balanced experimental groups for comparative endodontic laboratorial studies: a new proposal based on micro-CT and in silico methods
dc.typeJournal article
dc.creator.authorDe-Deus, Gustavo
dc.creator.authorSimões-Carvalho, M
dc.creator.authorBelladonna, Felipe Goncalves
dc.creator.authorVersiani, Marcio
dc.creator.authorSilva, E. J. N. L.
dc.creator.authorCavalcante, D. M.
dc.creator.authorSouza, E.M.
dc.creator.authorJohnsen, Gaute Floer
dc.creator.authorHaugen, Håvard Jostein
dc.creator.authorPaciornik, S.
cristin.unitcode185,16,0,0
cristin.unitnameDet odontologiske fakultet
cristin.ispublishedtrue
cristin.fulltextpreprint
cristin.qualitycode2
dc.identifier.cristin1800490
dc.identifier.bibliographiccitationinfo:ofi/fmt:kev:mtx:ctx&ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=International Endodontic Journal&rft.volume=&rft.spage=&rft.date=2020
dc.identifier.jtitleInternational Endodontic Journal
dc.identifier.volume53
dc.identifier.issue7
dc.identifier.startpage974
dc.identifier.endpage985
dc.identifier.doihttps://doi.org/10.1111/iej.13288
dc.identifier.urnURN:NBN:no-80698
dc.type.documentTidsskriftartikkel
dc.source.issn0143-2885
dc.identifier.fulltextFulltext https://www.duo.uio.no/bitstream/handle/10852/77609/1/IEJ-19-00783.R2_Proof_hi.pdf
dc.type.versionSubmittedVersion


Files in this item

Appears in the following Collection

Hide metadata