Hide metadata

dc.date.accessioned2020-06-15T18:17:06Z
dc.date.available2020-06-15T18:17:06Z
dc.date.created2020-02-04T12:59:59Z
dc.date.issued2019
dc.identifier.citationTronstad, Christian Høgetveit, Jan Olav Elvebakk, Ole Kalvøy, Håvard . Age-related differences in the morphology of the impedance cardiography signal. Journal of Electrical Bioimpedance. 2019, 10(1), 139-145
dc.identifier.urihttp://hdl.handle.net/10852/76959
dc.description.abstractImpedance cardiography (ICG) is a non-invasive method of hemodynamic measurement, mostly known for estimation of stroke volume and cardiac output based on characteristic features of the signal. Compared with electrocardiography, the knowledge on the morphology of the ICG signal is scarce, especially with respect to age-dependent changes in ICG waveforms. Based on recordings from ten younger (20–29 years) and ten older (60–79) healthy human subjects after three different levels of physical activity, the typical interbeat ICG waveforms were derived based on ensemble averages. Comparison of these waveforms between the age groups indicates the following differences: a later initial upward deflection for the younger group, an additional hump in the waveform from many older subjects not presented in the younger group, and a more pronounced second wave in the younger group. The explanation for these differences is not clear, but may be related to arterial stiffness. Further studies are suggested to determine whether these morphological differences have clinical value.
dc.languageEN
dc.publisherJournal of Electrical Bioimpedance
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Unported
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/3.0/
dc.titleAge-related differences in the morphology of the impedance cardiography signal
dc.typeJournal article
dc.creator.authorTronstad, Christian
dc.creator.authorHøgetveit, Jan Olav
dc.creator.authorElvebakk, Ole
dc.creator.authorKalvøy, Håvard
cristin.unitcode185,15,4,30
cristin.unitnameElektronikk
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1
dc.identifier.cristin1790707
dc.identifier.bibliographiccitationinfo:ofi/fmt:kev:mtx:ctx&ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Journal of Electrical Bioimpedance&rft.volume=10&rft.spage=139&rft.date=2019
dc.identifier.jtitleJournal of Electrical Bioimpedance
dc.identifier.volume10
dc.identifier.issue1
dc.identifier.startpage139
dc.identifier.endpage145
dc.identifier.doihttps://doi.org/10.2478/joeb-2019-0020
dc.identifier.urnURN:NBN:no-80052
dc.type.documentTidsskriftartikkel
dc.type.peerreviewedPeer reviewed
dc.source.issn1891-5469
dc.identifier.fulltextFulltext https://www.duo.uio.no/bitstream/handle/10852/76959/1/%255B18915469%2B-%2BJournal%2Bof%2BElectrical%2BBioimpedance%255D%2BAge-related%2Bdifferences%2Bin%2Bthe%2Bmorphology%2Bof%2Bthe%2Bimpedance%2Bcardiography%2Bsignal.pdf
dc.type.versionPublishedVersion


Files in this item

Appears in the following Collection

Hide metadata

Attribution-NonCommercial-NoDerivs 3.0 Unported
This item's license is: Attribution-NonCommercial-NoDerivs 3.0 Unported