Hide metadata

dc.date.accessioned2018-12-11T13:03:50Z
dc.date.available2018-12-11T13:03:50Z
dc.date.created2018-03-25T22:36:02Z
dc.date.issued2018
dc.identifier.citationLindstrøm, Carl A. Adli, Erik Allen, J. M. An, W. Beekman, C. Clarke, C. I. Clayton, C. E. Corde, S. Doche, A. Frederico, J. Gessner, S. J. Green, S. Z. Hogan, M.J. Joshi, C. Litos, M. Lu, W. Marsh, K. A. Mori, W. B. O'Shea, B. D. Vafaei-Najafabadi, N. Yakimenko, V. . Measurement of Transverse Wakefields Induced by a Misaligned Positron Bunch in a Hollow Channel Plasma Accelerator. Physical Review Letters. 2018, 120
dc.identifier.urihttp://hdl.handle.net/10852/65915
dc.description.abstractHollow channel plasma wakefield acceleration is a proposed method to provide high acceleration gradients for electrons and positrons alike: a key to future lepton colliders. However, beams which are misaligned from the channel axis induce strong transverse wakefields, deflecting beams and reducing the collider luminosity. This undesirable consequence sets a tight constraint on the alignment accuracy of the beam propagating through the channel. Direct measurements of beam misalignment-induced transverse wakefields are therefore essential for designing mitigation strategies. We present the first quantitative measurements of transverse wakefields in a hollow plasma channel, induced by an off-axis 20 GeV positron bunch, and measured with another 20 GeV lower charge trailing positron probe bunch. The measurements are largely consistent with theory.en_US
dc.languageEN
dc.publisherAmerican Physical Society
dc.relation.ispartofLindstrøm, Carl Andreas (2019) Emittance growth and preservation in a plasma-based linear collider. Doctoral thesis http://urn.nb.no/URN:NBN:no-69347
dc.relation.urihttp://urn.nb.no/URN:NBN:no-69347
dc.rightsAttribution 4.0 International
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.titleMeasurement of Transverse Wakefields Induced by a Misaligned Positron Bunch in a Hollow Channel Plasma Acceleratoren_US
dc.title.alternativeENEngelskEnglishMeasurement of Transverse Wakefields Induced by a Misaligned Positron Bunch in a Hollow Channel Plasma Accelerator
dc.typeJournal articleen_US
dc.creator.authorLindstrøm, Carl A.
dc.creator.authorAdli, Erik
dc.creator.authorAllen, J. M.
dc.creator.authorAn, W.
dc.creator.authorBeekman, C.
dc.creator.authorClarke, C. I.
dc.creator.authorClayton, C. E.
dc.creator.authorCorde, S.
dc.creator.authorDoche, A.
dc.creator.authorFrederico, J.
dc.creator.authorGessner, S. J.
dc.creator.authorGreen, S. Z.
dc.creator.authorHogan, M.J.
dc.creator.authorJoshi, C.
dc.creator.authorLitos, M.
dc.creator.authorLu, W.
dc.creator.authorMarsh, K. A.
dc.creator.authorMori, W. B.
dc.creator.authorO'Shea, B. D.
dc.creator.authorVafaei-Najafabadi, N.
dc.creator.authorYakimenko, V.
cristin.unitcode185,15,4,60
cristin.unitnameHøyenergifysikk
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode2
dc.identifier.cristin1575637
dc.identifier.bibliographiccitationinfo:ofi/fmt:kev:mtx:ctx&ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Physical Review Letters&rft.volume=120&rft.spage=&rft.date=2018
dc.identifier.jtitlePhysical Review Letters
dc.identifier.volume120
dc.identifier.pagecount5
dc.identifier.doihttp://dx.doi.org/10.1103/PhysRevLett.120.124802
dc.identifier.urnURN:NBN:no-68426
dc.subject.nviVDP::Kjerne- og elementærpartikkelfysikk: 431VDP::Rom- og plasmafysikk: 437
dc.type.documentTidsskriftartikkelen_US
dc.type.peerreviewedPeer reviewed
dc.source.issn0031-9007
dc.identifier.fulltextFulltext https://www.duo.uio.no/bitstream/handle/10852/65915/2/PhysRevLett.120.124802.pdf
dc.type.versionPublishedVersion
cristin.articleid124802
dc.relation.projectNFR/230450


Files in this item

Appears in the following Collection

Hide metadata

Attribution 4.0 International
This item's license is: Attribution 4.0 International