Hide metadata

dc.date.accessioned2018-08-31T07:32:41Z
dc.date.available2019-04-14T22:47:51Z
dc.date.created2017-08-03T10:46:25Z
dc.date.issued2017
dc.identifier.citationLevernæs, Maren Christin Stillesby Nordlund, Marianne Sparby Reubsaet, Leon Halvorsen, Trine Grønhaug . To elute or not to elute in immunocapture bottom-up LC?MS. Journal of chromatography. B. 2017, 1055-1056, 51-60
dc.identifier.urihttp://hdl.handle.net/10852/64001
dc.description.abstractImmunocapture-based bottom-up LC–MS is a promising technique for the quantification of low abundant proteins. Magnetic immunocapture beads provide efficient enrichment from complex samples through the highly specific interaction between the target protein and its antibody. In this article, we have performed the first thorough comparison between digestion of proteins while bound to antibody coated beads versus after elution from the beads. Two previously validated immunocapture based MS methods for the quantification of pro-gastrin releasing peptide (ProGRP) and human chorionic gonadotropin (hCG) were used as model systems. The tryptic peptide generation was shown to be protein dependent and influenced by protein folding and accessibility towards trypsin both on-beads and in the eluate. The elution of proteins bound to the beads was also shown to be incomplete. In addition, the on-beads digestion suffered from non-specific binding of the trypsin generated peptides. A combination of on-beads digestion and elution may be applied to improve both the quantitative (peak area of the signature peptides) and qualitative yield (number of missed cleavages, total number of identified peptides, coverage, signal intensity and number of zero missed cleavage peptides) of the target proteins. The quantitative yield of signature peptides was shown to be reproducible in all procedures tested.en_US
dc.languageEN
dc.titleTo elute or not to elute in immunocapture bottom-up LC–MSen_US
dc.title.alternativeENEngelskEnglishTo elute or not to elute in immunocapture bottom-up LC–MS
dc.typeJournal articleen_US
dc.creator.authorLevernæs, Maren Christin Stillesby
dc.creator.authorNordlund, Marianne Sparby
dc.creator.authorReubsaet, Leon
dc.creator.authorHalvorsen, Trine Grønhaug
cristin.unitcode185,15,23,20
cristin.unitnameFarmasøytisk kjemi
cristin.ispublishedtrue
cristin.fulltextpostprint
cristin.qualitycode1
dc.identifier.cristin1483955
dc.identifier.bibliographiccitationinfo:ofi/fmt:kev:mtx:ctx&ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Journal of chromatography. B&rft.volume=1055-1056&rft.spage=51&rft.date=2017
dc.identifier.jtitleJournal of chromatography. B
dc.identifier.volume1055-1056
dc.identifier.startpage51
dc.identifier.endpage60
dc.identifier.doihttp://dx.doi.org/10.1016/j.jchromb.2017.03.044
dc.identifier.urnURN:NBN:no-66544
dc.type.documentTidsskriftartikkelen_US
dc.type.peerreviewedPeer reviewed
dc.source.issn1570-0232
dc.identifier.fulltextFulltext https://www.duo.uio.no/bitstream/handle/10852/64001/1/To%2Belute%2Bor%2Bnot%2Bto%2Belute%2Bin%2Bimmunocapture%2Bbottom-up%2BLCMS.pdf
dc.type.versionAcceptedVersion


Files in this item

Appears in the following Collection

Hide metadata