Hide metadata

dc.date.accessioned2018-07-16T07:56:16Z
dc.date.available2018-07-16T07:56:16Z
dc.date.created2017-04-24T13:55:43Z
dc.date.issued2017
dc.identifier.citationHamre, Charlotta Botolfsen, Pernille Tangen, Gro Gujord Helbostad, Jorunn L. . Interrater and test-retest reliability and validity of the Norwegian version of the BESTest and mini-BESTest in people with increased risk of falling. BMC Geriatrics. 2017, 17(92), 1-8
dc.identifier.urihttp://hdl.handle.net/10852/62263
dc.description.abstractBackground: The Balance Evaluation Systems Test (BESTest) was developed to assess underlying systems for balance control in order to be able to individually tailor rehabilitation interventions to people with balance disorders. A short form, the Mini-BESTest, was developed as a screening test. The study aimed to assess interrater and test-retest reliability of the Norwegian version of the BESTest and the Mini-BESTest in community-dwelling people with increased risk of falling and to assess concurrent validity with the Fall Efficacy Scale-International (FES-I), and it was an observational study with a cross-sectional design. Methods: Forty-two persons with increased risk of falling (elderly over 65 years of age, persons with a history of stroke or Multiple Sclerosis) were assessed twice by two raters. Relative reliability was analysed with Intraclass Correlation Coefficient (ICC), and absolute reliability with standard error of measurement (SEM) and smallest detectable change (SDC). Concurrent validity was assessed against the FES-I using Spearman’s rho. Results: The BESTest showed very good interrater reliability (ICC = 0.98, SEM = 1.79, SDC95 = 5.0) and test-retest reliability (rater A/rater B = ICC = 0.89/0.89, SEM = 3.9/4.3, SDC95 = 10.8/11.8). The Mini-BESTest also showed very good interrater reliability (ICC = 0.95, SEM = 1.19, SDC95 = 3.3) and test-retest reliability (rater A/rater B = ICC = 0.85/0.84, SEM = 1.8/1.9, SDC95 = 4.9/5.2). The correlations were moderate between the FES-I and both the BESTest and the Mini-BESTest (Spearman’s rho −0.51 and-0.50, p < 0.01). Conclusion: The BESTest and its short form, the Mini-BESTest, showed very good interrater and test-retest reliability when assessed in a heterogeneous sample of people with increased risk of falling. The concurrent validity measured against the FES-I showed moderate correlation. The results are comparable with earlier studies and indicate that the Norwegian versions can be used in daily clinic and in research.en_US
dc.languageEN
dc.publisherBioMed Central
dc.rightsAttribution 4.0 International
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.titleInterrater and test-retest reliability and validity of the Norwegian version of the BESTest and mini-BESTest in people with increased risk of fallingen_US
dc.typeJournal articleen_US
dc.creator.authorHamre, Charlotta
dc.creator.authorBotolfsen, Pernille
dc.creator.authorTangen, Gro Gujord
dc.creator.authorHelbostad, Jorunn L.
cristin.unitcode185,52,10,0
cristin.unitnameAvdeling for helsefag
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1
dc.identifier.cristin1466234
dc.identifier.bibliographiccitationinfo:ofi/fmt:kev:mtx:ctx&ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=BMC Geriatrics&rft.volume=17&rft.spage=1&rft.date=2017
dc.identifier.jtitleBMC Geriatrics
dc.identifier.volume17
dc.identifier.issue92
dc.identifier.startpage1
dc.identifier.endpage8
dc.identifier.doihttp://dx.doi.org/10.1186/s12877-017-0480-x
dc.identifier.urnURN:NBN:no-64851
dc.type.documentTidsskriftartikkelen_US
dc.type.peerreviewedPeer reviewed
dc.source.issn1471-2318
dc.identifier.fulltextFulltext https://www.duo.uio.no/bitstream/handle/10852/62263/1/Hamre_BMCgeriatrics_BESTtest_2017.pdf
dc.type.versionPublishedVersion


Files in this item

Appears in the following Collection

Hide metadata

Attribution 4.0 International
This item's license is: Attribution 4.0 International