Hide metadata

dc.date.accessioned2017-06-28T10:57:19Z
dc.date.available2017-06-28T10:57:19Z
dc.date.created2017-06-28T10:02:54Z
dc.date.issued2017
dc.identifier.citationEvju, Øyvind Pozo, Jose M. Frangi, Alejandro F. Mardal, Kent-Andre . Robustness of common hemodynamic indicators with respect to numerical resolution in 38 middle cerebral artery aneurysms. PLoS ONE. 2017, 12(6)
dc.identifier.urihttp://hdl.handle.net/10852/55768
dc.description.abstractBackground: Using computational fluid dynamics (CFD) to compute the hemodynamics in cerebral aneurysms has received much attention in the last decade. The usability of these methods depends on the quality of the computations, highlighted in recent discussions. The purpose of this study is to investigate the convergence of common hemodynamic indicators with respect to numerical resolution. Methods: 38 middle cerebral artery bifurcation aneurysms were studied at two different resolutions (one comparable to most studies, and one finer). Relevant hemodynamic indicators were collected from two of the most cited studies, and were compared at the two refinements. In addition, correlation to rupture was investigated. Results: Most of the hemodynamic indicators were very well resolved at the coarser resolutions, correlating with the finest resolution with a correlation coefficient >0.95. The oscillatory shear index (OSI) had the lowest correlation coefficient of 0.83. A logarithmic Bland-Altman plot revealed noticeable variations in the proportion of the aneurysm under low shear, as well as in spatial and temporal gradients not captured by the correlation alone. Conclusion: Statistically, hemodynamic indicators agree well across the different resolutions studied here. However, there are clear outliers visible in several of the hemodynamic indicators, which suggests that special care should be taken when considering individual assessment.en_US
dc.languageEN
dc.publisherPublic Library of Science (PLoS)
dc.rightsAttribution 4.0 International
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.titleRobustness of common hemodynamic indicators with respect to numerical resolution in 38 middle cerebral artery aneurysmsen_US
dc.typeJournal articleen_US
dc.creator.authorEvju, Øyvind
dc.creator.authorPozo, Jose M.
dc.creator.authorFrangi, Alejandro F.
dc.creator.authorMardal, Kent-Andre
cristin.unitcode185,53,18,10
cristin.unitnameAvdeling for medisinsk genetikk
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1
dc.identifier.cristin1479389
dc.identifier.bibliographiccitationinfo:ofi/fmt:kev:mtx:ctx&ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=PLoS ONE&rft.volume=12&rft.spage=&rft.date=2017
dc.identifier.jtitlePLoS ONE
dc.identifier.volume12
dc.identifier.issue6
dc.identifier.doihttps://doi.org/10.1371/journal.pone.0177566
dc.identifier.urnURN:NBN:no-58529
dc.type.documentTidsskriftartikkelen_US
dc.type.peerreviewedPeer reviewed
dc.source.issn1932-6203
dc.identifier.fulltextFulltext https://www.duo.uio.no/bitstream/handle/10852/55768/2/journal.pone.0177566.pdf
dc.type.versionPublishedVersion


Files in this item

Appears in the following Collection

Hide metadata

Attribution 4.0 International
This item's license is: Attribution 4.0 International