dc.identifier.citationChen, Xiangjun Stojanovic, Aleksandar Hua, Yanjun Eidet, Jon Roger Hu, Di Wang, Jingting Utheim, Tor Paaske . Reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyes. PLoS ONE. 2014, 9(10)
dc.identifier.urihttp://hdl.handle.net/10852/43548
dc.description.abstractPurpose To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK) eyes and compare the results between these two groups. Methods Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs) were calculated. Univariate analysis of covariance (ANCOVA) was used to compare measured parameters between virgin and post-PRK eyes. Results The intraocular pressure (IOP), central corneal thickness (CCT) and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC≧0.90) in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC≧0.88). The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05) and negatively with deformation amplitude (r = −0.384 and −0.375, respectively, p<0.05) in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29±0.21 vs. 6.96±0.17 ms, p<0.05) and lower deformation amplitude (1.06±0.07 vs. 1.17±0.08 mm, p<0.05). Conclusions CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter.en_US
dc.languageEN
dc.language.isoenen_US
dc.publisherPublic Library of Science (PLoS)
dc.rightsAttribution 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.titleReliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyesen_US
dc.typeJournal articleen_US
dc.creator.authorChen, Xiangjun
dc.creator.authorStojanovic, Aleksandar
dc.creator.authorHua, Yanjun
dc.creator.authorEidet, Jon Roger
dc.creator.authorHu, Di
dc.creator.authorWang, Jingting
dc.creator.authorUtheim, Tor Paaske
cristin.unitcode185,53,12,12
cristin.unitnameØyeavdelingen
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1
dc.identifier.cristin1163392
dc.identifier.bibliographiccitationinfo:ofi/fmt:kev:mtx:ctx&ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=PLoS ONE&rft.volume=9&rft.spage=&rft.date=2014
dc.identifier.jtitlePLoS ONE
dc.identifier.volume9
dc.identifier.issue10
dc.identifier.doihttp://dx.doi.org/10.1371/journal.pone.0109577
dc.identifier.urnURN:NBN:no-47919
dc.type.documentTidsskriftartikkelen_US
dc.type.peerreviewedPeer reviewed
dc.source.issn1932-6203
dc.identifier.fulltextFulltext https://www.duo.uio.no/bitstream/handle/10852/43548/2/journal-pone-0109577chen.pdf
dc.type.versionPublishedVersion
cristin.articleide109577


Files in this item

Appears in the following Collection

Hide metadata

Attribution 4.0 International
This item's license is: Attribution 4.0 International