dc.identifier.citationBersvendsen, Jørn Beitnes, Jan Otto Urheim, Stig Aakhus, Svend Samset, Eigil . Automatic measurement of aortic annulus diameter in 3-dimensional transoesophageal echocardiography. BMC Medical Imaging. 2014, 14(31)
dc.identifier.urihttp://hdl.handle.net/10852/42596
dc.description.abstractBackground Transcatheter aortic valve implantation involves percutaneously implanting a biomechanical aortic valve to treat severe aortic stenosis. In order to select a proper device, precise sizing of the aortic valve annulus must be completed. Methods In this paper, we describe a fully automatic segmentation method to measure the aortic annulus diameter in patients with aortic calcification, operating on 3-dimensional transesophageal echocardiographic images. The method is based on state estimation of a subdivision surface representation of the left ventricular outflow tract and aortic root. The state estimation is solved by an extended Kalman filter driven by edge detections normal to the subdivision surface. Results The method was validated on echocardiographic recordings of 16 patients. Comparison against two manual measurements showed agreements (mean ±SD) of -0.3±1.6 and -0.2±2.3 mm for perimeter-derived diameters, compared to an interobserver agreement of -0.1±2.1 mm. Conclusions With this study, we demonstrated the feasibility of an efficient and fully automatic measurement of the aortic annulus in patients with aortic disease. The algorithm robustly measured the aortic annulus diameter, providing measurements indistinguishable from those done by cardiologists.en_US
dc.languageEN
dc.language.isoenen_US
dc.publisherBioMed Central
dc.relation.ispartofBersvendsen, Jørn (2016) Segmentation of cardiac structures in 3-dimensional echocardiography. Doctoral thesis. http://urn.nb.no/URN:NBN:no-54101
dc.relation.urihttp://urn.nb.no/URN:NBN:no-54101
dc.rightsAttribution 2.0 Generic
dc.rights.urihttp://creativecommons.org/licenses/by/2.0/
dc.titleAutomatic measurement of aortic annulus diameter in 3-dimensional transoesophageal echocardiographyen_US
dc.typeJournal articleen_US
dc.creator.authorBersvendsen, Jørn
dc.creator.authorBeitnes, Jan Otto
dc.creator.authorUrheim, Stig
dc.creator.authorAakhus, Svend
dc.creator.authorSamset, Eigil
cristin.unitcode185,15,5,0
cristin.unitnameInstitutt for informatikk
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1
dc.identifier.cristin1225210
dc.identifier.bibliographiccitationinfo:ofi/fmt:kev:mtx:ctx&ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=BMC Medical Imaging&rft.volume=14&rft.spage=&rft.date=2014
dc.identifier.jtitleBMC Medical Imaging
dc.identifier.volume14
dc.identifier.doihttp://dx.doi.org/10.1186/1471-2342-14-31
dc.identifier.urnURN:NBN:no-46998
dc.type.documentTidsskriftartikkelen_US
dc.type.peerreviewedPeer reviewed
dc.source.issn1471-2342
dc.identifier.fulltextFulltext https://www.duo.uio.no/bitstream/handle/10852/42596/1/1471-2342-14-31.pdf
dc.type.versionPublishedVersion
cristin.articleid31


Files in this item

Appears in the following Collection

Hide metadata

Attribution 2.0 Generic
This item's license is: Attribution 2.0 Generic