dc.identifier.citationLenæs, Guro. Sammenlikning av øyetrykkmålinger utført med 3 portable tonometre av medisinstudent med måling utført med Goldmans applanasjonstonometer av erfaren øyelege. Prosjektoppgave, University of Oslo, 2007en_US
dc.identifier.urihttp://hdl.handle.net/10852/29858
dc.description.abstractBackground: Glaucoma is a disease with progressive and irreversible optic neuropathy, and a leading cause of blindness worldwide. Complications of glaucoma can be delayed or prevented. General practitioners (GPs) should measure intra ocular pressure (IOP) in patients with symptoms of or risk factors for acute or chronic elevated IOP. There are several portable tonometers commercially available. Objective: Compare the use of three portable tonometers by an inexperienced tonometrist, concerning IOP readings, time consumption and patient comfort. Material: 20 volunteers with no past ocular pathology with a mean age of 27 years (range 21–37 years). Method: IOP was measured in both eyes by a medical student with Schiotz’ tonometer, TonoPen and ICare, and compared with a gold standard; IOP readings with Goldmann’s applanation tonometer by an experienced tonometrist. Time consumption and patient comfort were recorded and compared regarding local anaesthesia and the three portable tonometers. Results: Mean IOP readings in the right and left eye were 13,5 ± 1,9 mmHg (range 10-18) and 13,6 ± 1,8 mmHg (range 10-18), 15,9 mmHg ± 3,2 (range 11-22) and 14,9 ± 2,3 mmHg (range 11-19), 14,5 ± 2,4 mmHg (range 10-20) and 14,1 ± 2,5 mmHg (range 11-19), 10,7 ± 3,0 mmHg (range 6,5-15,9) and 11,1 ± 2,8 mmHg (range 7,1-17,3), for Goldmann, ICare, TonoPen and Schiotz’, respectively. IOP readings of the three portable tonometers differed significantly (p=0,05) from those of Goldmanns applanation tonometer, apart from TonoPen’s of IOP in the left eye. The application of local anaesthesia yielded the highest reported level of patient discomfort. The reported levels of discomfort from IOP readings were highest after use of Schiotz’, then TonoPen and ICare, in decreasing succession. Mean time consumption for IOP readings were 68,6 ± 22,9 sec (range 44-129), 84,3 ± 41,3 sec (range 55-244) and 131,4 ± 61,3 sec (range 74-299) for ICare, TonoPen and Schiotz’, respectively. Conclusion: The accuracy of Schiotz’, ICare and TonoPen is acceptable for screening purposes. Shiotz’, however, shows lower IOP values than the gold standard. In this study, TonoPen was the most userfriendly of the three. Not requiring local anaesthesia gives ICare an advantage in measuring IOP, especially in children.nor
dc.language.isonoben_US
dc.subjectøyesykdommer
dc.titleSammenlikning av øyetrykkmålinger utført med 3 portable tonometre av medisinstudent med måling utført med Goldmans applanasjonstonometer av erfaren øyelegeen_US
dc.typeMaster thesisen_US
dc.date.updated2008-03-13en_US
dc.creator.authorLenæs, Guroen_US
dc.subject.nsiVDP::754en_US
dc.identifier.bibliographiccitationinfo:ofi/fmt:kev:mtx:ctx&ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:dissertation&rft.au=Lenæs, Guro&rft.title=Sammenlikning av øyetrykkmålinger utført med 3 portable tonometre av medisinstudent med måling utført med Goldmans applanasjonstonometer av erfaren øyelege&rft.inst=University of Oslo&rft.date=2007&rft.degree=Prosjektoppgaveen_US
dc.identifier.urnURN:NBN:no-17930en_US
dc.type.documentProsjektoppgaveen_US
dc.identifier.duo68872en_US
dc.contributor.supervisorLiv Drolsumen_US
dc.identifier.bibsys080409717en_US
dc.identifier.fulltextFulltext https://www.duo.uio.no/bitstream/handle/10852/29858/3/ProsjektLenas.pdf


Files in this item

Appears in the following Collection

Hide metadata