dc.identifier.citationHenriksen, Hege Berg Henriksen, Christine Sequeira de Sousa, Ana Rita Alavi, Dena Helene Augestad, Elin Marie Rising, Russell Dörner, Rebecca Hägele, Franziska A. Bosy-Westphal, Anja Blomhoff, Rune Ulven, Stine Marie Olsen, Thomas . Validity and reproducibility of a whole-room indirect calorimeter for the estimation of VO2, VCO2, and resting metabolic rate. Physiological Reports. 2023, 11(7)
dc.identifier.urihttp://hdl.handle.net/10852/107924
dc.description.abstractAbstract Whole‐room indirect calorimeters (WRICs) provide accurate instruments for the measurement of respiratory exchange, energy expenditure, and macronutrient oxidation. Here, we aimed to determine the validity and reproducibility of a 7500 L WRIC for the measurement of ventilation rates and resting metabolic rate (RMR). Technical validation was performed with propane combustion tests ( n  = 10) whereas biological reproducibility was tested in healthy subjects (13 women, 6 men, mean ± SD age 39.6 ± 15.3) in two 60 min measurements separated by 24 h. Subjects followed a run‐in protocol prior to measurements. The coefficient of variation (CV) and intraclass correlation coefficient (ICC) were calculated for ventilation rates of O2 (VO2), CO2 (VCO2), the respiratory quotient (RQ; VCO2/VO2), and RMR. Technical validation showed good validity with CVs ranging from 0.67% for VO 2 to 1.00% for energy expenditure. For biological reproducibility, CVs were 2.89% for VO 2 ; 2.67% for VCO 2 ; 1.95% for RQ; and 2.68% for RMR. With the exception of RQ (74%), ICCs were excellent for VO 2 (94%), VCO 2 (96%) and RMR (95%). Excluding participants that deviated from the run‐in protocol did not alter results. In conclusion, the 7500 L WRIC is technically valid and reproducible for ventilation rates and RMR.
dc.languageEN
dc.rightsAttribution 4.0 International
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.titleValidity and reproducibility of a whole-room indirect calorimeter for the estimation of VO2, VCO2, and resting metabolic rate
dc.title.alternativeENEngelskEnglishValidity and reproducibility of a whole-room indirect calorimeter for the estimation of VO2, VCO2, and resting metabolic rate
dc.typeJournal article
dc.creator.authorHenriksen, Hege Berg
dc.creator.authorHenriksen, Christine
dc.creator.authorSequeira de Sousa, Ana Rita
dc.creator.authorAlavi, Dena Helene
dc.creator.authorAugestad, Elin Marie
dc.creator.authorRising, Russell
dc.creator.authorDörner, Rebecca
dc.creator.authorHägele, Franziska A.
dc.creator.authorBosy-Westphal, Anja
dc.creator.authorBlomhoff, Rune
dc.creator.authorUlven, Stine Marie
dc.creator.authorOlsen, Thomas
cristin.unitcode185,51,13,0
cristin.unitnameAvdeling for ernæringsvitenskap
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1
dc.identifier.cristin2139735
dc.identifier.bibliographiccitationinfo:ofi/fmt:kev:mtx:ctx&ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Physiological Reports&rft.volume=11&rft.spage=&rft.date=2023
dc.identifier.jtitlePhysiological Reports
dc.identifier.volume11
dc.identifier.issue7
dc.identifier.doihttps://doi.org/10.14814/phy2.15658
dc.type.documentTidsskriftartikkel
dc.type.peerreviewedPeer reviewed
dc.source.issn2051-817X
dc.type.versionPublishedVersion
cristin.articleide15658


Files in this item

Appears in the following Collection

Hide metadata

Attribution 4.0 International
This item's license is: Attribution 4.0 International