Hide metadata

dc.date.accessioned2024-01-15T18:09:23Z
dc.date.available2024-01-15T18:09:23Z
dc.date.created2023-05-23T11:06:55Z
dc.date.issued2023
dc.identifier.citationHovd, Markus Herberg Robertsen, Ida Woillard, Jean-Baptiste Åsberg, Anders . A Method for Evaluating Robustness of Limited Sampling Strategies—Exemplified by Serum Iohexol Clearance for Determination of Measured Glomerular Filtration Rate. Pharmaceutics. 2023, 15(4), 1-12
dc.identifier.urihttp://hdl.handle.net/10852/106835
dc.description.abstractIn combination with Bayesian estimates based on a population pharmacokinetic model, limited sampling strategies (LSS) may reduce the number of samples required for individual pharmacokinetic parameter estimations. Such strategies reduce the burden when assessing the area under the concentration versus time curves (AUC) in therapeutic drug monitoring. However, it is not uncommon for the actual sample time to deviate from the optimal one. In this work, we evaluate the robustness of parameter estimations to such deviations in an LSS. A previously developed 4-point LSS for estimation of serum iohexol clearance (i.e., dose/AUC) was used to exemplify the effect of sample time deviations. Two parallel strategies were used: (a) shifting the exact sampling time by an empirical amount of time for each of the four individual sample points, and (b) introducing a random error across all sample points. The investigated iohexol LSS appeared robust to deviations from optimal sample times, both across individual and multiple sample points. The proportion of individuals with a relative error greater than 15% (P15) was 5.3% in the reference run with optimally timed sampling, which increased to a maximum of 8.3% following the introduction of random error in sample time across all four time points. We propose to apply the present method for the validation of LSS developed for clinical use.
dc.languageEN
dc.rightsAttribution 4.0 International
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.titleA Method for Evaluating Robustness of Limited Sampling Strategies—Exemplified by Serum Iohexol Clearance for Determination of Measured Glomerular Filtration Rate
dc.title.alternativeENEngelskEnglishA Method for Evaluating Robustness of Limited Sampling Strategies—Exemplified by Serum Iohexol Clearance for Determination of Measured Glomerular Filtration Rate
dc.typeJournal article
dc.creator.authorHovd, Markus Herberg
dc.creator.authorRobertsen, Ida
dc.creator.authorWoillard, Jean-Baptiste
dc.creator.authorÅsberg, Anders
cristin.unitcode185,15,23,30
cristin.unitnameSeksjon for farmakologi og farmasøytisk
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1
dc.identifier.cristin2148669
dc.identifier.bibliographiccitationinfo:ofi/fmt:kev:mtx:ctx&ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Pharmaceutics&rft.volume=15&rft.spage=1&rft.date=2023
dc.identifier.jtitlePharmaceutics
dc.identifier.volume15
dc.identifier.issue4
dc.identifier.doihttps://doi.org/10.3390/pharmaceutics15041073
dc.type.documentTidsskriftartikkel
dc.type.peerreviewedPeer reviewed
dc.source.issn1999-4923
dc.type.versionPublishedVersion
cristin.articleid1073


Files in this item

Appears in the following Collection

Hide metadata

Attribution 4.0 International
This item's license is: Attribution 4.0 International